{"id":4974,"date":"2026-07-18T12:22:31","date_gmt":"2026-07-18T16:22:31","guid":{"rendered":"https:\/\/dhnglass.com\/glass-railing-height-requirements\/"},"modified":"2026-09-17T21:28:26","modified_gmt":"2026-09-18T01:28:26","slug":"glass-railing-height-requirements","status":"publish","type":"post","link":"https:\/\/dhnglass.com\/fr\/glass-railing-height-requirements\/","title":{"rendered":"Hauteurs de rampes en verre : les normes expliqu\u00e9es (2026)"},"content":{"rendered":"<p class=\"wp-block-paragraph\">Si vous planifiez une rampe en verre, la premi\u00e8re question qui compte vraiment n'est ni le style ni le prix \u2014 c'est <strong>quelle hauteur doit-elle l\u00e9galement avoir ?<\/strong> Trompez-vous et c'est l'inspection \u00e9chou\u00e9e et la recommande. La bonne nouvelle : les r\u00e8gles sont plus simples qu'elles en ont l'air, une fois qu'on sait laquelle des quatre situations s'applique.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><em>Petite mise en garde avant les chiffres : les codes du b\u00e2timent sont adopt\u00e9s <strong>juridiction par juridiction et amend\u00e9s localement<\/strong>. Les chiffres ci-dessous sont les bases des codes mod\u00e8les dont partent la plupart des juridictions (IRC, IBC, ISPSC) \u2014 confirmez toujours l'exigence finale avec votre service du b\u00e2timent avant de commander.<\/em><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Les quatre r\u00e8gles de hauteur qui couvrent presque tous les projets<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">1. Terrasses et balcons : 36 po \u2014 parfois 42 po<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Selon l'International Residential Code (IRC), toute terrasse, tout balcon ou toute surface de circulation \u00e0 plus de <strong>30 pouces au-dessus du sol<\/strong> exige un garde-corps. Pour le r\u00e9sidentiel, la base est une <strong>hauteur minimale de 36 pouces<\/strong>; plusieurs \u00c9tats et municipalit\u00e9s l'amendent \u00e0 <strong>42 pouces<\/strong>, et 42 po est aussi le standard des immeubles multilogements.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The DHN Glass system installs at <strong>36, 42 ou 48 po<\/strong> depending on the panel you choose, so both standards are covered off the shelf.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">2. Cl\u00f4tures de piscine : 48 po minimum<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Les barri\u00e8res de piscine ont leur propre r\u00e8glement \u2014 typiquement l'International Swimming Pool and Spa Code (ISPSC) ou une loi locale sur la s\u00e9curit\u00e9 des piscines. La base : une <strong>hauteur de barri\u00e8re minimale de 48 pouces<\/strong>, des ouvertures qui refusent une sph\u00e8re de 4 pouces, et une <strong>porte auto-fermante et auto-verrouillante<\/strong>. Certains \u00c9tats vont plus loin \u2014 la Californie, par exemple, exige couramment <strong>60 pouces<\/strong> selon ses dispositions locales de s\u00e9curit\u00e9 des piscines.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Glass is popular here for a reason: no horizontal members to climb.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">3. Escaliers : garde-corps 34 po + main courante pr\u00e9hensible \u00e0 34-38 po<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">L'escalier combine deux exigences. Le <strong>garde-corps<\/strong> le long du c\u00f4t\u00e9 ouvert d'une vol\u00e9e exige typiquement un minimum de <strong>34 pouces mesur\u00e9s verticalement au nez de marche<\/strong> (36 po et plus sur un palier). S\u00e9par\u00e9ment, la plupart des codes exigent une <strong>main courante pr\u00e9hensible plac\u00e9e de 34 \u00e0 38 pouces au-dessus des nez de marche<\/strong> on stairs with four or more risers \u2014 the glass panel itself doesn&#8217;t satisfy this; a rail does.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">4. Commercial : base de 42 po<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">H\u00f4tels, restaurants, bureaux et autres usages IBC exigent typiquement des <strong>garde-corps de 42 pouces<\/strong>, stricter glazing provisions (laminated glass or a continuous top rail in some editions and jurisdictions), and engineered documentation. Commercial glass projects should be specified per project \u2014 that&#8217;s exactly what our commercial glass railing team does, stamped drawings included.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">La hauteur n'est pas toute l'histoire : charges et ouvertures<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Les inspecteurs n'apportent pas qu'un ruban \u00e0 mesurer. Les garde-corps sont aussi \u00e9valu\u00e9s contre les charges des codes mod\u00e8les : une <strong>charge concentr\u00e9e de 200 lb<\/strong> appliqu\u00e9e au sommet, et <strong>50 lb par pied lin\u00e9aire<\/strong> le long de la rampe. Et aucune ouverture ne doit laisser passer une <strong>sph\u00e8re de 4 pouces<\/strong> .<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">This is where hardware grade matters more than glass. Every DHN Glass spigot and connector is machined from #2205 duplex stainless steel and engineered around those guard loads.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Aide-m\u00e9moire<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Application<\/th><th>Hauteur minimale typique<\/th><th>Points cl\u00e9s<\/th><\/tr><\/thead><tbody><tr><td>Terrasse \/ balcon r\u00e9sidentiel<\/td><td>36 po (42 po dans certaines juridictions)<\/td><td>Garde-corps requis d\u00e8s 30 po de d\u00e9nivel\u00e9<\/td><\/tr><tr><td>Barri\u00e8re de piscine<\/td><td>48 po (60 po dans certains \u00c9tats, p. ex. la Californie)<\/td><td>Porte \u00e0 fermeture et verrouillage automatiques<\/td><\/tr><tr><td>Vol\u00e9e d'escalier<\/td><td>34 po au nez de marche<\/td><td>+ main courante pr\u00e9hensible \u00e0 34-38 po<\/td><\/tr><tr><td>Commercial (IBC)<\/td><td>42&#8243;<\/td><td>Ing\u00e9nierie par projet, dispositions sur le vitrage<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><em>(Bases des codes mod\u00e8les \u2014 vos amendements locaux priment. Confirmez avant de commander.)<\/em><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Comment viser la bonne hauteur sur votre commande<\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>Appelez votre service du b\u00e2timent<\/strong> (ou consultez vos documents de permis) et demandez la hauteur de garde-corps requise et toute disposition sur le vitrage pour votre type de projet.<\/li>\n\n\n\n<li><strong>Choisissez la hauteur de panneau correspondante<\/strong> \u2014 le <a href=\"https:\/\/dhnglass.com\/fr\/configurateur-2d\/\">configurateur 2D<\/a> permet de r\u00e9gler des hauteurs finies de 36, 42 ou 48 po et calcule le prix de votre am\u00e9nagement exact instantan\u00e9ment.<\/li>\n\n\n\n<li><strong>Pas certain ?<\/strong> Envoyez-nous votre am\u00e9nagement et votre juridiction \u2014 notre \u00e9quipe le r\u00e9vise et peut fournir un support d'ing\u00e9nierie si votre permis l'exige. Ou commencez par notre <a href=\"https:\/\/dhnglass.com\/fr\/how-much-does-glass-railing-cost-2026\/\">guide complet des co\u00fbts<\/a> et notre <a href=\"https:\/\/dhnglass.com\/fr\/how-to-install-frameless-glass-railing-diy\/\">guide d'installation DIY<\/a>.<\/li>\n<\/ol>\n\n\n\n<h2 class=\"wp-block-heading\">Questions fr\u00e9quentes<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Une rampe de 36 pouces suffit-elle pour ma terrasse ?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">In most U.S. jurisdictions, yes \u2014 the IRC baseline for residential decks is 36&#8243;. But several states and many municipalities require 42&#8243;, and multi-family buildings typically do too. Confirm with your local building department; the DHN Glass system covers both with 36&#8243;, 42&#8243; and 48&#8243; panels.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Les rampes en verre doivent-elles respecter les m\u00eames hauteurs que les autres rampes ?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Oui. Les exigences de hauteur, de charge et d'ouverture s'appliquent au garde-corps peu importe le mat\u00e9riau. Le verre ajoute des dispositions propres au vitrage (verre de s\u00e9curit\u00e9 tremp\u00e9, et exigences de lamin\u00e9 ou de main courante dans certaines juridictions commerciales).<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Une rampe en verre se mesure-t-elle au sommet du verre ?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Pour un syst\u00e8me sans cadre sans main courante, la hauteur requise se mesure au bord sup\u00e9rieur du verre. Si une main courante est pos\u00e9e, la mesure va jusqu'au sommet de celle-ci. Dans les deux cas, on mesure depuis la surface de circulation \u2014 ou depuis le nez de marche dans les vol\u00e9es.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Que se passe-t-il si ma rampe est trop basse \u00e0 l'inspection ?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">L'inspecteur refuse le garde-corps et il faudra le mettre \u00e0 hauteur \u2014 ce qui signifie habituellement remplacer les panneaux, pas les caler. C'est l'erreur la plus co\u00fbteuse de la cat\u00e9gorie, et la plus facile \u00e0 \u00e9viter : confirmez le chiffre avant de commander.<\/p>\n\n\n\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/dhnglass.com\/fr\/configurateur-2d\/\">Concevoir ma rampe en verre<\/a><\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Glass railing height requirements explained: 36&#8243; vs 42&#8243; guards, 48&#8243; pool barriers, 34&#8243;\u201338&#8243; stair handrails, loads and openings \u2014 with a state-by-state caution.<\/p>","protected":false},"author":7,"featured_media":4459,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_yoast_wpseo_opengraph-title":"","_yoast_wpseo_opengraph-description":"","footnotes":""},"categories":[252],"tags":[],"class_list":["post-4974","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-buyers-guide"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.5 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Glass Railing Height Requirements: U.S. Codes Explained (2026) - DHN Glass<\/title>\n<meta name=\"robots\" content=\"noindex, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<meta property=\"og:locale\" content=\"fr_CA\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Glass Railing Height Requirements: U.S. Codes Explained (2026) - DHN Glass\" \/>\n<meta property=\"og:description\" content=\"Glass railing height requirements explained: 36&quot; vs 42&quot; guards, 48&quot; pool barriers, 34&quot;\u201338&quot; stair handrails, loads and openings \u2014 with a state-by-state caution.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/dhnglass.com\/fr\/glass-railing-height-requirements\/\" \/>\n<meta property=\"og:site_name\" content=\"DHN Glass\" \/>\n<meta property=\"article:published_time\" content=\"2026-07-18T16:22:31+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-09-18T01:28:26+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/dhnglass.com\/wp-content\/uploads\/2026\/06\/groupe-eno-hero-rampe-verre-toronto.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"1184\" \/>\n\t<meta property=\"og:image:height\" content=\"864\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"author\" content=\"Muaz Dahan\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u00c9crit par\" \/>\n\t<meta name=\"twitter:data1\" content=\"Muaz Dahan\" \/>\n\t<meta name=\"twitter:label2\" content=\"Estimation du temps de lecture\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/dhnglass.com\\\/glass-railing-height-requirements\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/dhnglass.com\\\/glass-railing-height-requirements\\\/\"},\"author\":{\"name\":\"Muaz Dahan\",\"@id\":\"https:\\\/\\\/dhnglass.com\\\/#\\\/schema\\\/person\\\/317336d2ee7aecbfa2ddfae1f54d4c3f\"},\"headline\":\"Glass Railing Height Requirements: U.S. Codes Explained (2026)\",\"datePublished\":\"2026-07-18T16:22:31+00:00\",\"dateModified\":\"2026-09-18T01:28:26+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/dhnglass.com\\\/glass-railing-height-requirements\\\/\"},\"wordCount\":829,\"publisher\":{\"@id\":\"https:\\\/\\\/dhnglass.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/dhnglass.com\\\/glass-railing-height-requirements\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/dhnglass.com\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/groupe-eno-hero-rampe-verre-toronto.webp\",\"articleSection\":[\"Buyer's Guide\"],\"inLanguage\":\"fr-CA\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/dhnglass.com\\\/glass-railing-height-requirements\\\/\",\"url\":\"https:\\\/\\\/dhnglass.com\\\/glass-railing-height-requirements\\\/\",\"name\":\"Glass Railing Height Requirements: U.S. Codes Explained (2026) - DHN Glass\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/dhnglass.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/dhnglass.com\\\/glass-railing-height-requirements\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/dhnglass.com\\\/glass-railing-height-requirements\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/dhnglass.com\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/groupe-eno-hero-rampe-verre-toronto.webp\",\"datePublished\":\"2026-07-18T16:22:31+00:00\",\"dateModified\":\"2026-09-18T01:28:26+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/dhnglass.com\\\/glass-railing-height-requirements\\\/#breadcrumb\"},\"inLanguage\":\"fr-CA\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/dhnglass.com\\\/glass-railing-height-requirements\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-CA\",\"@id\":\"https:\\\/\\\/dhnglass.com\\\/glass-railing-height-requirements\\\/#primaryimage\",\"url\":\"https:\\\/\\\/dhnglass.com\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/groupe-eno-hero-rampe-verre-toronto.webp\",\"contentUrl\":\"https:\\\/\\\/dhnglass.com\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/groupe-eno-hero-rampe-verre-toronto.webp\",\"width\":1184,\"height\":864,\"caption\":\"groupe eno hero rampe verre toronto\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/dhnglass.com\\\/glass-railing-height-requirements\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/dhnglass.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Glass Railing Height Requirements: U.S. Codes Explained (2026)\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/dhnglass.com\\\/#website\",\"url\":\"https:\\\/\\\/dhnglass.com\\\/\",\"name\":\"Groupe ENO | Rampes en verre\",\"description\":\"Premium Tempered Glass Railings\",\"publisher\":{\"@id\":\"https:\\\/\\\/dhnglass.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/dhnglass.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-CA\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/dhnglass.com\\\/#organization\",\"name\":\"DHN Glass\",\"alternateName\":\"DHN Group, Inc.\",\"url\":\"https:\\\/\\\/dhnglass.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-CA\",\"@id\":\"https:\\\/\\\/dhnglass.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/dhnglass.com\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/DHN_Glass_emblem_512-1.png\",\"contentUrl\":\"https:\\\/\\\/dhnglass.com\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/DHN_Glass_emblem_512-1.png\",\"width\":512,\"height\":512,\"caption\":\"DHN Glass\"},\"image\":{\"@id\":\"https:\\\/\\\/dhnglass.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/dhnglass.com\\\/#\\\/schema\\\/person\\\/317336d2ee7aecbfa2ddfae1f54d4c3f\",\"name\":\"Muaz Dahan\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-CA\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/da6d3623cf588ec9ba396086c5659e19c3bd4625c2f4847185636d8d9178a43e?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/da6d3623cf588ec9ba396086c5659e19c3bd4625c2f4847185636d8d9178a43e?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/da6d3623cf588ec9ba396086c5659e19c3bd4625c2f4847185636d8d9178a43e?s=96&d=mm&r=g\",\"caption\":\"Muaz Dahan\"},\"url\":\"https:\\\/\\\/dhnglass.com\\\/fr\\\/author\\\/infowlm9\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Glass Railing Height Requirements: U.S. Codes Explained (2026) - DHN Glass","robots":{"index":"noindex","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"og_locale":"fr_CA","og_type":"article","og_title":"Glass Railing Height Requirements: U.S. Codes Explained (2026) - DHN Glass","og_description":"Glass railing height requirements explained: 36\" vs 42\" guards, 48\" pool barriers, 34\"\u201338\" stair handrails, loads and openings \u2014 with a state-by-state caution.","og_url":"https:\/\/dhnglass.com\/fr\/glass-railing-height-requirements\/","og_site_name":"DHN Glass","article_published_time":"2026-07-18T16:22:31+00:00","article_modified_time":"2026-09-18T01:28:26+00:00","og_image":[{"width":1184,"height":864,"url":"https:\/\/dhnglass.com\/wp-content\/uploads\/2026\/06\/groupe-eno-hero-rampe-verre-toronto.webp","type":"image\/webp"}],"author":"Muaz Dahan","twitter_card":"summary_large_image","twitter_misc":{"\u00c9crit par":"Muaz Dahan","Estimation du temps de lecture":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/dhnglass.com\/glass-railing-height-requirements\/#article","isPartOf":{"@id":"https:\/\/dhnglass.com\/glass-railing-height-requirements\/"},"author":{"name":"Muaz Dahan","@id":"https:\/\/dhnglass.com\/#\/schema\/person\/317336d2ee7aecbfa2ddfae1f54d4c3f"},"headline":"Glass Railing Height Requirements: U.S. Codes Explained (2026)","datePublished":"2026-07-18T16:22:31+00:00","dateModified":"2026-09-18T01:28:26+00:00","mainEntityOfPage":{"@id":"https:\/\/dhnglass.com\/glass-railing-height-requirements\/"},"wordCount":829,"publisher":{"@id":"https:\/\/dhnglass.com\/#organization"},"image":{"@id":"https:\/\/dhnglass.com\/glass-railing-height-requirements\/#primaryimage"},"thumbnailUrl":"https:\/\/dhnglass.com\/wp-content\/uploads\/2026\/06\/groupe-eno-hero-rampe-verre-toronto.webp","articleSection":["Buyer's Guide"],"inLanguage":"fr-CA"},{"@type":"WebPage","@id":"https:\/\/dhnglass.com\/glass-railing-height-requirements\/","url":"https:\/\/dhnglass.com\/glass-railing-height-requirements\/","name":"Glass Railing Height Requirements: U.S. Codes Explained (2026) - DHN Glass","isPartOf":{"@id":"https:\/\/dhnglass.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/dhnglass.com\/glass-railing-height-requirements\/#primaryimage"},"image":{"@id":"https:\/\/dhnglass.com\/glass-railing-height-requirements\/#primaryimage"},"thumbnailUrl":"https:\/\/dhnglass.com\/wp-content\/uploads\/2026\/06\/groupe-eno-hero-rampe-verre-toronto.webp","datePublished":"2026-07-18T16:22:31+00:00","dateModified":"2026-09-18T01:28:26+00:00","breadcrumb":{"@id":"https:\/\/dhnglass.com\/glass-railing-height-requirements\/#breadcrumb"},"inLanguage":"fr-CA","potentialAction":[{"@type":"ReadAction","target":["https:\/\/dhnglass.com\/glass-railing-height-requirements\/"]}]},{"@type":"ImageObject","inLanguage":"fr-CA","@id":"https:\/\/dhnglass.com\/glass-railing-height-requirements\/#primaryimage","url":"https:\/\/dhnglass.com\/wp-content\/uploads\/2026\/06\/groupe-eno-hero-rampe-verre-toronto.webp","contentUrl":"https:\/\/dhnglass.com\/wp-content\/uploads\/2026\/06\/groupe-eno-hero-rampe-verre-toronto.webp","width":1184,"height":864,"caption":"groupe eno hero rampe verre toronto"},{"@type":"BreadcrumbList","@id":"https:\/\/dhnglass.com\/glass-railing-height-requirements\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/dhnglass.com\/"},{"@type":"ListItem","position":2,"name":"Glass Railing Height Requirements: U.S. Codes Explained (2026)"}]},{"@type":"WebSite","@id":"https:\/\/dhnglass.com\/#website","url":"https:\/\/dhnglass.com\/","name":"Groupe ENO | Rampes en verre","description":"Premium Tempered Glass Railings","publisher":{"@id":"https:\/\/dhnglass.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/dhnglass.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-CA"},{"@type":"Organization","@id":"https:\/\/dhnglass.com\/#organization","name":"DHN Glass","alternateName":"DHN Group, Inc.","url":"https:\/\/dhnglass.com\/","logo":{"@type":"ImageObject","inLanguage":"fr-CA","@id":"https:\/\/dhnglass.com\/#\/schema\/logo\/image\/","url":"https:\/\/dhnglass.com\/wp-content\/uploads\/2026\/09\/DHN_Glass_emblem_512-1.png","contentUrl":"https:\/\/dhnglass.com\/wp-content\/uploads\/2026\/09\/DHN_Glass_emblem_512-1.png","width":512,"height":512,"caption":"DHN Glass"},"image":{"@id":"https:\/\/dhnglass.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/dhnglass.com\/#\/schema\/person\/317336d2ee7aecbfa2ddfae1f54d4c3f","name":"Muaz Dahan","image":{"@type":"ImageObject","inLanguage":"fr-CA","@id":"https:\/\/secure.gravatar.com\/avatar\/da6d3623cf588ec9ba396086c5659e19c3bd4625c2f4847185636d8d9178a43e?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/da6d3623cf588ec9ba396086c5659e19c3bd4625c2f4847185636d8d9178a43e?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/da6d3623cf588ec9ba396086c5659e19c3bd4625c2f4847185636d8d9178a43e?s=96&d=mm&r=g","caption":"Muaz Dahan"},"url":"https:\/\/dhnglass.com\/fr\/author\/infowlm9\/"}]}},"_links":{"self":[{"href":"https:\/\/dhnglass.com\/fr\/wp-json\/wp\/v2\/posts\/4974","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/dhnglass.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/dhnglass.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/dhnglass.com\/fr\/wp-json\/wp\/v2\/users\/7"}],"replies":[{"embeddable":true,"href":"https:\/\/dhnglass.com\/fr\/wp-json\/wp\/v2\/comments?post=4974"}],"version-history":[{"count":2,"href":"https:\/\/dhnglass.com\/fr\/wp-json\/wp\/v2\/posts\/4974\/revisions"}],"predecessor-version":[{"id":5382,"href":"https:\/\/dhnglass.com\/fr\/wp-json\/wp\/v2\/posts\/4974\/revisions\/5382"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/dhnglass.com\/fr\/wp-json\/wp\/v2\/media\/4459"}],"wp:attachment":[{"href":"https:\/\/dhnglass.com\/fr\/wp-json\/wp\/v2\/media?parent=4974"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/dhnglass.com\/fr\/wp-json\/wp\/v2\/categories?post=4974"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/dhnglass.com\/fr\/wp-json\/wp\/v2\/tags?post=4974"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}